چکیده:   (5107 مشاهده)

BACKGROUND

 Reconstruction of complex soft tissue defects of the thumb, with exposure of tendons, joints or bones, has always been a difficult task. We evaluated the functional and esthetic outcomes of 1st dorsal metacarpal artery island flap in reconstruction of post-traumatic soft tissue defects of the thumb.

METHODS

Between January 2012 and June 2014, fifteen patients with complex post-traumatic soft tissue thumb defects underwent 1st dorsal metacarpal artery island flap. Sensory function was evaluated with static 2-point discrimination and cortical reorientation. The mobility of the thumb was tested by the Kapandji score. The esthetic outcome was assessed. Patient's subjective satisfaction was evaluated by the visual analogue scale.

RESULTS

 The mean flap size was 33.3×17.7 mm. All donor sites were grafted by full-thickness skin grafts from the groin. Fourteen flaps survived completely and one had distal flap necrosis was treated conservatively. The mean static two-point discrimination was 10.4 mm. Cortical reorientation was complete in 40%. The average Kapandji score was 7.1. The esthetic outcome was excellent in six, good in eight and poor in one subject. After a mean follow up period of 18.2 months, the mean subjective satisfaction score was 8.1; most patients regained all functions of the thumb and index finger and were pleased with the cosmetic appearance of the flap and donor site.

CONCLUSION

First dorsal metacarpal artery flap offers a sensate, pliable and versatile coverage for small to moderate sized thumb defects. Moreover, it provides good functional and esthetic outcomes with minimal donor site morbidity.

     
نوع مطالعه: مقالات اصيل | موضوع مقاله: تخصصي
انتشار الکترونیک: 1396/11/3

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.

کلیه حقوق این وب سایت متعلق به مجله جهانی جراحی پلاستیک می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2024 CC BY-NC 4.0 | World Journal of Plastic Surgery

Designed & Developed by : Yektaweb