Abstract:   (4660 Views)
BACKGROUND In recent years, there is an increasing tendency to use diced cartilage grafts in rhinoplasty surgery for improving dorsum contour irregularities. This study was designed to compare graft resorption between three techniques of diced cartilage using surgical blade, electrical grinder and grater in rabbit model. METHODS Thirteen New Zealand rabbits were divided into three groups. Three 2×2 cm cartilage specimens were harvested from one of their ears. In group one, the cartilage was diced by use of No:11 surgical blade to o.5 to 1 mm cube pieces. In group two, an electrical grinder was used and in group three, a grater was applied. The grafts were placed in three subcutaneous pockets in the back of rabbits and after 12 weeks, the implants were removed and their weight and volume were recorded and were evaluated by histological techniques. RESULTS There was no difference between the three methods in the 3 groups for graft resorption. There was no change in the volume, but the weight showed a decrease in the control group. CONCLUSIONS As the histological results had no statistically difference between groups, we may recommend use of these two techniques in reconstructive and in aesthetic cases.
Keywords: Graft resorption; Diced cartilage; Blade; Grinder; Grater; Rabbit
Full-Text [PDF 2515 kb]   (2699 Downloads)    
Type of Study: Original Article | Subject: Special
Received: 2013/11/4 | Accepted: 2013/11/4 | Published: 2013/11/4
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA code


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Manafi A, Sabet M, Emami A, Vasei M, Mosavi J, Manafi A, et al . A Comparasion in Graft Resorption between Three Techniques of Diced Cartilage Using Surgical Blade, Electrical Grinder and Grater in Rabbit. wjps. 2014; 3 (1) :52-63
URL: http://wjps.ir/article-1-90-en.html


Volume 3, Issue 1 (1-2014) Back to browse issues page
مجله جهانی جراحی پلاستیک World Journal of Plastic Surgery
Persian site map - English site map - Created in 0.06 seconds with 31 queries by YEKTAWEB 3790